Mastco's
Monitoring Systems
|

Contact
us to receive a
full color brochure on our line
of Monitoring equipment
-or-
Download brochure in
pdf format
(1020KB)
Viewing
this document
requires
acrobat reader.
Click on the Icon below in order to download the reader which is
compatible with your system.

info@mastco.net
1(877)-6-MASTCO
1(877)-662-7826
|
|
Developed for the Protection, Monitoring and Management
of Humanities most Priceless Resources

Mastco's Temperature
Monitoring System was designed with traceability and validation throughout.
Audible and visual alarms, archiving functions, tamperproof settings
and multiple printouts are just some of our features.
Mastco's monitoring
systems include distinctive features that managers, supervisors, and
technicians need but find lacking in other makes of temperature monitors.
All products are specifically designed with the customer in mind and
to conform to all regulatory requirements.
The essential prerequisites of a temperature monitoring system are
ease of viewing, ease of operation, management, and essentially reliability.
Our three key Product lines are AlarmLog,
ScanLog, and the MSM
Our encapsulated
PTFE temperature probes come standard with most of Mastco's Monitors
including AlarmLogs and DuaLogs!
The
Mastco team is extremely proud of our temperature monitoring systems
and is convinced you will find one perfect for your needs.
Mastco's temperature range of -200° C to +200° C
(-328° F to +392° F) is the best in the industry.
We also
have two travel loggers, TraveLog and CryoLog.
All of our monitoring systems or loggers operate either in a stand-alone
mode or in conjunction with a PC using custom Window based software.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SCANLOG
SPECIFICATIONS
|
|
|
Mastco's Scanlog is the heart of our
10 to 80-channel system

Drag mouse
over image to view close up of Scanlog
ScanLog
allows you to grow using your existing AlarmLogs and DuaLogs therefore
not
wasting valuable resources when you exceed your AlarmLog MultiPoint system.
Scanlog
generates both an audible and visual alarm whenever an out-of-limit
condition occurs. No cryptic fault codes or unrecognizable channel number
will appear
since you define both the title and error message.
SCANLOG
INSTALLATION GUIDE
Part I - Central Scanner Installation &
Connection
Part II - Commissioning Guide
Part III -Software Installation & PC Commissioning
|
|
|
|
|
|
|
|
|
|
System
Capacity
|
1/80
Channels
|
|
Display
|
4-line
x 40
Character LCD
|
|
Resolution
|
0.1°
C
|
|
Accuracy
|
+/-0.2°
C
|
|
Data
Log
|
As
Loggers
|
|
Event
Log
|
512
Entries
|
|
Logging
Interval
|
As
Loggers
|
|
Measurement
Rate
|
As
Loggers
|
|
Channel
Titles
|
Set
by User
|
|
Alarm
Messages
|
Set
by User
|
|
Alarm
Features
|
Alarm
Key
Six Alarm Zones
|
|
Alarm
Delay
|
0/99
minutes
|
|
Data
Security
|
Settings
Key
System, Multi-level Password
|
|
Back-up
Battery
|
12V,
Float Charged,
7-Days Capacity
|
|
Temperature
Range
|
-200°
C to +200°
C
(-328°
F to +392°F)
|
|
Dimensions
|
450
x350 x60mm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LOGGERS
SPECIFICATIONS |
|
Our
AlarmLog is a single channel battery powered monitor

Drag mouse
over image to view close up of AlarmLog
AlarmLogs can be
used as either a portable unit or wall mounted.
They may be used independently or up to ten units to create a MultiPoint
system.
A full range of installation accessories make the system simple to
install and easy to expand.

Drag mouse
over image to view close up of DuaLog
The DuaLog
is basically a two-channel AlarmLog without a
LCD display or keypad. The primary advantage is that a customer
receives a two-channel system for about the same cost of one AlarmLog.
.
|
|
|
|
|
|
|
|
| AlarmLog
|
Single
Channel |
| DuaLog |
Dual
Channel
(without display) |
| Resolution |
0.1°
C |
| Accuracy |
+/-0.2°
C |
| Data
Log |
3072
Points |
| Event
Log |
100
Entries |
| Logging
Interval |
1/99
minutes |
| Measurement
Rate |
Every
4 Seconds |
| Alarm
Delay |
0/99
minutes |
| Battery
Type |
2X
Alkaline AA |
| Battery
Life |
One
Year |
Temperature
Range |
-200°
C to +200°
C
(-328°
F to +392°F) |
| Dimensions |
80
x 150 x30mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MSM
SPECIFICATIONS |
|
|
MSM "Our Largest System"

Drag
mouse over image to view close up of MSM
Our MSM system consists
of two basic components, the Central Scanner
and Remote Sensor Units (RSUs). The Central Scanner continually monitors
each
RSU and maintains all channel history. The large six-line vacuum fluorescent
display (VFD)
shows precisely what the status is at each RSU location
The MSM and ScanLog
systems have many of the same features since
ScanLog was developed from the MSM system.
|
|
|
|
|
|
|
|
|
|
System
Capacity
|
90/360
Channels
|
|
Display
|
6-line
x 40
Character VFD
|
|
Resolution
|
0.1°
C
|
|
Accuracy
|
+/-0.2°
C
|
|
Data
Log
|
1984
Points
|
|
Event
Log
|
250
|
|
Logging
Interval
|
1/6
minutes
|
|
Measurement
Rate
|
9
Sensors a Second
|
|
Channel
Titles
|
Set
by User
|
|
Alarm
Messages
|
Set
by User
|
|
Alarm
Features
|
Alarm
Key
Ten Alarm Zones
|
|
Alarm
Delay
|
0/99
minutes
|
|
Data
Security
|
Settings
Key
System, Multi-level Password
|
|
Back-up
Battery
|
18V,
Float Charged,
6 Hour Capacity
|
|
Temperature
Range
|
-200°
C to +200°
C
(-328°
F to +392°F)
|
|
Dimensions
|
480
x320 x250mm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Our Travel Temperature Logger |
|
|
|
|
|
TravelLog
is ideal for transit temperature monitoring applications and was designed
with simplicity in mind. It combines cost-effective data logging with
a visual out-of-limits indication using red and green LEDs. The green
LED will continue to flash while temperatures are within the preset
range. If temperatures go beyond their preset range the red LED will
flash a warning of this out-of-limit condition. TraveLog has a operating
temperature range of -50° C to + 70°
C (-59° F to + 158°
F).
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mastco's Cryogenic Travel Logger |
|
|
|
|
|
CryoLog
was designed for shipments with dry ice but can be used in various applications.
The logger is attached on the external surface of shipping containers
with the PTFE probe inside next to your valuable shipment. CryoLog has
three LED indicators (Normal, Warning and Alarm) for safeguard and ease
of detecting problems during transport. Many other features are similar
to AlarmLog including Mastco's quality and dependability. CryoLog's
operating range is -100°
C to +20°
C (-148°
F to +68°
F).
|
|
|
 |
|
|
|
|
Quality is
Reliability
ISO 9001 registration covers the design and manufacture of our Temperature
Monitor,
Alarm and Logging System and associated applications software.
A one-year parts and
labor warranty and free telephone support for the lifetime
of your equipment shows our confidence in our systems. We include
free version
software upgrades for the life of your equipment.
Calibration
and Validation
Mastco will
provide a comprehensive calibration of all channels to ensure the
systems
meets or exceeds all regulatory requirements. Mastco's Calibration Units
are
NIST certified and our PC software will guide the non-technical user through
the calibration sequence for annual re-certification or an interim
quality check.
Calibration dates are stored within each logger and a certificate
is printed when completed.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |